Buy Cotherm - Replacement TSE 11' T115 16A 250V Immersion Thermostat TSE00187 Suitable for use with upper or lower Immersion Heaters on Unvented Cylinders at Unvented Components Europe - The UK leader in Unvented heating spares. Buy Cotherm TSE 11' T115 Immersion Thermostat TSE00187 Suitable for use with upper or lower Immersion Heaters at Unvented Components Europe. Cotherm - TSE 11 Cotherm - TSE 11. TSE 11' T115 16A 250V Immersion Thermostat TSE00187.
My sister has a Heatrae Sadia megaflo hot water tank with two immersion heaters for her hot water. Heating is separate, by storage heaters (no gas supply to flats).
The thermostats are 'COTHERM type: TSE T115'. There is a little red plastic switch labelled SAFETY which the electrician told her to 'pop out'. However, using a small screwdriver to press this switch does not release it out again. Should it, in fact, be pushed in? I ask both questions because I took the cover. Called out to flat with electric heated water tank with twin immersions (E7 & 24/7) type Cotherm type TSE both had tripped on the double pole safety cut-out. I reset and got immersion & hot water back on owner claims immersion trips every 3 weeks or so and previous electrician claims its a fault with most of. What are the temperature setting on a Cotherm TSE 00187 Thermostat? 1 = 10°C, 2 = 25°C. Single control thermostat with a second manual reset over.
She has had some problems, and an electrician has been called a couple of times. Last time, he told her how to reset the thermostat if it tripped. However, there are a couple of things I'd like advice on, please. From my reading so far, I think that the lower immersion heater is the overnight timed one, and the upper is the boost one - is this always the case? The thermostats are 'COTHERM type: TSE T115'. There is a little red plastic switch labelled SAFETY which the electrician told her to 'pop out'.
However, using a small screwdriver to press this switch does not release it out again. Should it, in fact, be pushed in? I ask both questions because I took the cover off the lower stat and the switch is level with the blue surround, whereas the top one (which the electrician adjusted last time) is depressed.
How To Install Mtnl Adsl Modem. However, the boost currently works and the main water heating does not. Finally, if this happens again, is it most likely to be a dodgy stat, or will the whole element need replacing?
Sorry for the long post, thanks in advance for any advice. The only time a reset button should be used is when you have two forms of heating for example solid fuel. In a way you do have two forms of heating as you have two elements and since thermosyphon will cause water at top to also be heated from bottom element then top one can trip due to fault in bottom one. Since Megaflow is an un-vented system I would be worried about the trip and would want to replace the thermostat. The boost is always top and storage bottom again because of thermosyphon. Because the Megaflow is a special it may work at higher than boiling temperatures so thermostats need careful selection.
Not really done much work on them most around here seem to use Glenhill as unlike Megaflow they don't need annual inspections as not pressurised. I'm with Ericmark. The only time I have seen a CoTherm trip in an all-electric Megaflo is when the owner drained down the system and left the elements powered up The red button should be depressed to just below level with the blue housing. If you have a test meter, there are two test points on the stat (marked 1 and 2) you should get 230V between them with the power and the reset on and the thermostat turned up.
You'll only be able to do this on the lower element during the off peak times. I'm not sure at what temp the safety trip on these goes off. I think the standard is 90ºC. Check the temperature setting on the stats and make sure its not set on maximum. From April 2004, new and replacement Immersion Heater Thermostats need to incorporate an overheat safety cut-out. They are fiited as standard to comply with regs.
I would expect the lower thermostat to be set to a lower temperature than the upper one. When the cylinder is heated, there will be a temperatue gradient from hottest at the top of the cylinder, cooling towards the bottom. Hot water rises, just like hot air.
If the lower thermostat is set too high, the thermosyphon could heat water at the top of the cylinder enough to trip the cutout in the upper heater before the water at the bottom of the cylinder gets hot enough to operate the lower heater's thermostat. You could try setting the lower 'stat temperature about 10 degrees lower than the operating temperature the upper cutout operates at, then 20 degrees etc.
Until you find a point where the upper cutout doesn't trip.
Terms and conditions of the sale • Payment - All payments must be received within 7 days of auction end. Cheques must be drawn on a UK bank account. Please allow 5 working days for clearance of cheques from date of receipt.
Made payable to 'Household Spares Ltd' • Postage - Postal charges are clearly shown within the auction listing. Please bear in mind that our postal charges include more than the price of a stamp and includes actual postage costs, packaging and handling. If you bid, you are deemed to have accepted the shipping charges quoted. International shipping may be subject to import duties or other taxes. • Dispatch Terms and Conditions Order will usually be dispatched within 24 hours (Monday - Friday).
Orders placed after 1pm Friday, Saturday or Sunday will be dispatched on Monday. Our standard delivery is Royal Mail 1st class (unless order is oversized). If you require your item urgently we do offer Royal Mail special delivery or courier next working day.
There is an additional cost for this service.Please contact us ASAP if you require this service and it is not in the postage options at [email protected]. Orders for next working day delivery need to be placed before 1pm Monday – Friday. Orders sent out on Friday special delivery are not guaranteed to arrive Saturday as Royal mail do not guarantee Saturday delivery. Orders place after 1pm will be dispatched the following day Monday – Friday only. We reserve the right to use our courier service where appropriate irrespective of delivery method selected. We do not dispatch on Bank Holidays.
Order due for dispatch on a Bank Holiday will be dispatched the next working day. We will always try our upmost to resolve any issues you may have so please contact us if you have any problems or questions Please contact us through ebay. • 100% 30 Day Money Back Guarantee - Under the Distance Selling Regulations, if you buy online or by phone, your consumer rights entitle you to a full refund if you request one in writing within 14 days of receipt.Spares4Homes Give a 30 Day returns Policy,Please contact us through ebay.You must retain proof of purchase to obtain refund. Items may be returned/exchanged provided that the item(s) are unused, in their original undamaged packaging, in a saleable condition. The consumer will be responsible for costs incurred in returning goods. All exchanges will incur a return shipping fee.
Items that are specially made to a buyer’s specification cannot be returned unless they are faulty. All returns must be returned With the receipt and details of reason for return. Returns without this information will not be Processed.
Please return to: Spares4homes Returns Unit 3 99 Gander Green Lane Sutton, Surrey SM12ES. **30 Days Returns Policy** Spares4homes offer a 30 Day full refund returns policy, Please write to [email protected] within 30 days of purchase, You must retain proof of purchase to obtain refund. Items may be returned/exchanged provided that the item(s) are unused, in their original undamaged packaging, in a saleable condition. The consumer will be responsible for costs incurred in returning goods. Exchanges may incur a return shipping fee. Items returned Used will not be refunded.
Items returned with damage/ written on packaging will incur a 30% handling fee Items that are specially made to a buyer’s specification cannot be returned unless they are faulty. PCB Boards are none returnable and exempt from 30 day returns policy.